The inlet flow is connected to V port, C with actuator port and 1/4"BSP Port to pilot pressure supply. The flow passes free from V to C. When descend control pressure is applied on pilot port it opens gradually and flow passes from C to V and does not allow the increased flow to increase the actuator speed. Note : The valve should be set 30% above max load induced pressure.
Pilot ratio 1:4.2
adjustment range 100-350bar
ports | 1/2"bsp |
---|---|
flow | 60lpm |
max pressure | 350bar |